358 Security Mesh Panels, Posts and Clamps

Specify a 358 fence as one fitted bay with the rectangular opening, wire, height, post and clamp positions shown on the same drawing. Relia lists a 2500 mm example with a 12.7 × 76.2 mm opening and 4 mm wire. Verify the chosen panel and its full fixing package against the project requirements.

Specification view
Aperture in both directions with the wire diameter and panel orientation
Fitted proof
At least one post and clamp assembly to review for the selected bay
High-density welded mesh on an equipment-compound perimeter

Read both dimensions of the rectangular opening

Relia lists a narrow-aperture 358 candidate. Send the approved layout and your selected fixing detail. We can start with the catalogue panel geometry and reconcile it with the ordered width, posts and the specified clamp arrangement. Use a dimensioned view because rotating a rectangular mesh changes the direction shown on site.

See the 2500 mm 358 panel and wire specifications

State which dimension runs vertically and horizontally. Give the opening definition, unit and wire-measurement method you need on the quote. A simple sketch or a marked drawing makes the comparison easier.

Close-up of the narrow rectangular openings of a 358 mesh panel
Panel geometry
Record whether the two 358 dimensions are opening or pitch and state wire diameter separately.
Clamping system
Use the actual post, clamp and fasteners on a finished sample.
Tender review
Request the drawing revision and approval evidence for the exact assembly quoted.

An aperture detail alongside the mounting line

Keep the mesh view and the post connection on the tender sheet. Buyers comparing narrow-aperture options can see both the geometry and the kit they need to install it.

Read the full tender row
Four places to check a complete 358 bay
  1. Opening detail
    Label the short and long directions of the clear opening and the nominal wire size.
  2. Panel extent
    Mark the panel height and the clearance to the base or ground in the assembled view.
  3. Fastening detail
    Show the specified post, clamp length and hole centres at the edge being fitted.
  4. Special bay
    Identify gate, end and corner connections that use a different arrangement from the line bay.

The tender row that identifies a complete 358 bay

Show which mesh dimension runs vertically and which horizontally. Keep tolerance and measurement method with the value so a buyer, installer and receiving inspector can all read the same tender row. Keep the quoted height, finish and fastener set on the same row as the aperture and wire.

Tender fieldRecord in the scheduleDrawing or evidence
Mesh geometry
Clear opening on two axes and nominal 4 mm wire for the example
Oriented section with measuring method and tolerance
Panel and ground
Finished panel height, panel width and installed top line
Plan and elevation at a flat bay, change in level and gate
Post and clamp
Selected square or rectangular section and clamp line
Hole layout, fastening arrangement and actual hardware list
Evidence
Finish by component, project specification and required tests
Applicable report for the ordered dimensions and assembly

Clamps and posts complete the panel quote

Tell us the preferred post section and attach the detail for a typical panel end. Confirm the fixing arrangement, gate-side condition and supplier scope before putting the quote into your tender sheet. Try the same clamping assembly against the two panel edges it will hold.

Attach the hardware to the exact panel line. The 2500 mm narrow-aperture example lists 12.7 × 76.2 mm mesh and 4 mm wire. Tie the selected post, clamp and fastener assemblies to the drawing revision for that option. Request a fitted edge view with clamp-hole centres and the finished gap at the post.

A dense welded mesh panel meeting its steel support post

From an approved layout to a comparable offer

A tender sheet works well when each proposed component has a part reference and source. Use a named approved bay drawing as the basis for comparing offers.

  1. SpecifyMark typical, corner and terminal details.
  2. ReviewCompare the quoted parts with the layout.
  3. RecordAttach matching drawings and any required evidence.

Review the special bays too

Take one pass through corners and ends before the order is final. A typical straight bay can establish the panel type. The end and corner positions still need their own agreed supports and connections. Separate changes of level and gate tie-ins from the repeat panel schedule.

A corner bay of dense rectangular security mesh outside a service compound

Narrow-aperture welding and clamp alignment

A 358 panel has closely spaced wires on one axis. A finished drawing must identify how that opening is measured and how the panel engages the receiving hardware. Agree panel dimensions and hole locations for the welding and coating review.

Opening, edge and fixings checked as one 358 bay
  1. Material and dimensionsRead 12.7 × 76.2 mm on both axes

    Record whether the listed dimensions are clear opening or pitch. Give the selected wire diameter and measurement basis separately.

  2. Fabrication and fitMeasure the welded grid after finishing

    Check the opening and edge trim on the finished panel before fitting it to the exact post and clamp called for.

  3. Inspection evidenceReview the complete assembly

    Use the actual fasteners and clamp on the sample. Request any required test evidence against that drawing and assembly revision.

Detailed checks for this order
  1. Set the mesh geometryWires are arranged on both axes and joined at intersections. State which dimension is the clear opening or pitch, and give the accepted wire diameter and tolerance separately.
  2. Keep the edges and finish measurableCheck trim at the top, bottom and sides. For a coated sample, measure finished opening and full panel width at the points designated on the drawing.
  3. Fit the clamp to the finished assemblyUse the exact post, bracket, fastener and edge detail. Ask for a dimension record and any specified test evidence that identifies the submitted assembly and drawing revision.

TWI guidance on resistance welding

The 2500 mm narrow-aperture example

Product descriptions are reference data for the shortlist. Use the dimensions and configuration in your approved project drawing to identify which sample and records you need. Use the listed values to shortlist a model and request the acceptance evidence that applies to your exact option.

  • 2500 mm 358 panel

    Details in the description
    2400 × 2500 mm nominal dimensions, width field 2000–3100 mm, 12.7 × 76.2 mm mesh and 4 mm wire
    Confirm before order
    Finished size and wire basis, aperture axes and square or rectangular post fit
  • Coating and fittings

    Details in the description
    Galvanized and powder-coated or PVC choices appear in the surface field
    Confirm before order
    Selected sequence by part, signed fittings drawing and evidence for that exact assembly

ASTM architectural metal fence standards

Browse related products · 358 Security Mesh Fencing

Compare with other rigid fence systems

Use the twin-wire guide for a separate structural family. If the plan keeps an existing 358 or welded panel, begin the post request with the existing measurements. Choose the related rigid-system guide when its opening or attachment fits a different requirement.

Send the panel and fitting schedule

Send the required aperture, panel height, finish and post or clamp drawing. Attach gate and end details plus any applicable acceptance criteria.

Panel
Height and two aperture dimensions
Supports
Posts, clamps and locations
Evidence
Required drawings and documents
Qingdao Relia Industries Co., Ltd.

Shuyuan Road, Qingdao, Shandong, China

About our fence business