Galvanized Palisade Bays for Industrial Fence Extensions

Start a palisade extension with a survey of one retained bay. Record pale profile, rail height, post spacing and how the first new bay joins the fence. Relia’s galvanized and powder-finish examples can help shortlist an option once the drawing shows the profile and the parts that will stay.

First site task
Survey a sound retained bay and photograph the pale profile
Release evidence
One fitted tie-in with a recorded rail alignment and chosen finish
Galvanized steel palisade bays along an industrial side boundary

The narrow profile determines the visual match

Relia lists galvanized and powder-coated palisade fence candidates. Send us an end photo, a pale cross-section and rail holes measured from one datum. We can review suitable catalogue options and identify which components still need a transition drawing. Pick a sound visible pale and record its shape and finish as the reference.

Review a galvanized and powder-coated palisade candidate

Photograph the pale face and side together. Measure the section and rail fixing pattern. A 6 ft catalogue height helps shortlist candidates, while the actual profile and connection fix the extension detail.

Galvanized palisade pale profile at the horizontal rail
Matching the existing elevation
Record the pale profile, centres and visible top detail on the retained bay.
Joining old and new rails
Use the same datum for hole centres and the end offset at the transition.
Before repeating the bay
Approve one finished pale, rail and fastener fit.

The retained end beside the new bay

Draw the old end first, then carry its rail and fixing heights into the proposed bay. The paired views give the installer a clear location for the first joint.

Prepare the separate tie-in view
Match the existing reference to the first new bay
  1. Retained bay
    Measure the pale profile, rail heights and spacing from a visible datum.
  2. Tie-in joint
    Show the rail end, fasteners and where the existing post or foundation remains.
  3. First new assembly
    Review the assembled section for alignment and finish before confirming all repeats.

A palisade tie-in measured at the retained end

Use an end-on pale photo and the same datum on the old and proposed rail. State whether spacing means centres or clear gap. Show post centres, rail elevations and the joint fastener positions on a common drawing.

InterfaceMeasure on the existing fenceVerify for the extension
Pale section
Profile, actual outer measurement, material thickness and spacing
Replacement profile and visible line match
Rail interface
Rail section and centre-to-centre hole position
Pattern, enough overlap and matching fasteners as drawn
End post
Outside section, old centre and offset to the adjacent bay
Connection position and finish on the actual post drawing

The tie-in needs its own view

A face drawing sets overall dimensions. Add a side view of the last post and rail end so we can see how the new section would meet them. Mark the change if the old bay is uneven or out of square. Give the fabricator the retained end profile and the space available for the connector.

Record the first joint beside the old rail. Use the industrial palisade range to shortlist the proposed finish and height. Give the fabricator a front and side view of the old rail end, plus the fastener spacing from the same datum. Request a drawing with the retained end and new bay identified separately.

An existing palisade end bay and a staged matching replacement section

Approve one matching section before the order

Choose a representative interface. Keeping that specific check with the order helps the installer and purchase team. Set a trial at the extension point while existing clearances can still be measured.

  1. MeasureKeep the datum on the old end.
  2. CompareUse the candidate section and rail drawing.
  3. ApproveRecord the agreed joint and selected coating.

Finish and spares go on separate order lines

Both catalogue candidates list galvanized and powder-coated finishes. Check the colour from a sample when the extension is visible. Include spare pale, rail or fastener parts as separate lines if your maintenance team needs them. Include spare corresponding fittings and visible finish requirements on distinct quote lines.

Closely spaced steel palisade parts laid out for a sample check

Pale forming and rail fit

A palisade bay depends on the selected pale section and the way it attaches to existing rails. Consider the profile, punched holes and finish together when checking the fit. Review the fixed rail against the chosen pale before releasing the finish or drilling schedule.

Three fit checks at an old-to-new palisade joint
  1. Material and dimensionsRecord the formed pale shape

    Start from a usable retained section. Note pale thickness, width and the top detail against an elevation.

  2. Fabrication and fitCompare rail holes from the same datum

    Mark their centres and end distance on both sections. Agree the zinc and powder sequence for the quoted parts before fitting.

  3. Inspection evidenceReview one finished transition bay

    Use the actual pale, rail and fastener in the trial. The result establishes the visible gap and the fitting reference for further bays.

Detailed checks for this order
  1. Define the pale cross-section and elevationPut the formed shape, width, thickness and top detail in the drawing. Include the spacing and the measuring points used on the retained bay.
  2. Check rail preparation against the existing endReference the hole centres and end offset from one datum. Compare a new pale, rail and fastener sample to the adjoining structure before confirming the remaining quantity.
  3. Inspect the finished tie-inConfirm the zinc and any powder-coat sequence by item. Check hole and fastener fit after coating and document the sample elevation so the finished extension can be compared to it.

American Galvanizers Association on galvanizing routes

Palisade product data and the drawing check

The shared specification lists vertical member spacing options of 100, 110 and 120 mm and a 1.2–3.0 mm thickness field. Another post option is ambiguously entered in the catalogue. Use the supplier drawing for exact post dimensions and determine whether each range applies to the pale, rail or post. Resolve profile, colour and mounting choices with a matching drawing before comparing listed items.

  • 6 ft palisade example

    Listed configuration
    7 × 6 ft nominal, 1800/2000/2400 mm width options, galvanized and powder-coated finish listed
    Confirm before order
    Real clear width, pale and rail section, colour sample
  • Industrial steel palisade

    Listed configuration
    1800/2100/3000 mm height options among other nominal fields, galvanized or galvanized and powder coated terms
    Confirm before order
    Agreed top line, post centre, joint and component coating

American Galvanizers Association duplex system guidance

Browse related products · Steel Palisade Fencing

Related fence profiles and post work

If the frontage uses picket fencing, quote that line from its own geometry. Use the post guide for the slab or ground interface of a new run. Check the post work guide if the extension uses a new footing or a retained mount.

Send photos of the end bay and a section drawing

Send photos and dimensions of the last sound bay, the tie-in joint, intended finish and extension length. Mark any gates or change in level.

Old fence
Pale, rail and terminal details
New run
Length, finish and positions
Fit
Required sample or connection drawing
Qingdao Relia Industries Co., Ltd.

Shuyuan Road, Qingdao, Shandong, China

About our fence business