2.1 m Australian-Style Temporary Fence Kits

A 2.1 m Australian-style temporary fence order covers the panel, the matching feet, the clamps and the stays required by the site. Relia lists a 2100 × 2400 mm panel candidate. Send the screened and open runs separately so the quote can show the assembled height, support interfaces and fittings per run.

Catalogue starting point
2100 × 2400 mm panel, subject to the selected option
Site input
Identify screened spans, returns, gates and ground conditions on the same plan
Temporary mesh panels with orange feet along an asphalt worksite

Open runs and screened runs have different inputs

Relia's 2.1 m construction panel lists 60 × 150 mm mesh and 3.5 or 4.0 mm wire options. Tell us whether your run is open or screened. We can identify the frame and base options for review with the installer.

Compare the 2.1 m panel and tube options

Mark the screened bays on your layout so the feet, braces and assembly information can be reviewed for those locations. Give screened and open runs separate quantities so the support review can follow the installed layout.

  • Open runRecord the layout, panel width and ground condition.
  • Screened runGive the proposed screen area and the project's approved wind conditions.
Open temporary run
Start with the 2100 × 2400 mm panel and check tube, foot and clamp on the same bay.
Run with screening
Mark the covered bays and use the approved wind and support conditions on the kit review.
Before releasing the kit
Record the chosen tube outside diameter and measured seating depth on a fitted sample.

The foot, leg and clamp on one drawing

Show the upper and lower interfaces in an assembled view. The sketch makes it easier to spot a leg or clamp that fits the panel on paper but sits differently at the actual site.

Review the assembled dimensions
Fit checks at the three assembly points
  1. Lower socket
    Record the opening, insertion depth and orientation of the feet.
  2. Frame leg
    Provide the outside tube dimension and the distance between the legs from the same datum.
  3. Top clamp
    Identify the tube sizes at the connection and the intended bolt position.
  4. Screened return
    Give the reviewer the screen coverage, ground surface and location of each return or stay.

The foot and the frame share one interface

The post tube and base opening determine the fit. Give us the outside tube diameter and a base photo if you already have feet on site. An assembly drawing can confirm the insertion depth and the height above the pavement. Add a straight-on socket photo beside a scale if you plan to mix replacement parts with existing feet.

Temporary panel frame seated in a removable base on pavement

The assembled dimensions to put on the quote

The panel width is a useful stock reference. Centrelines, end returns and the base arrangement determine the installed run and finished height. Keep the dimensions that control the assembly on the same drawing. Write the frame dimensions and the assembled run dimensions in separate columns on the order sheet.

A quote entry the site crew can check. The 2100 × 2400 mm construction panel is listed with a 3.5 mm wire option. Record the chosen wire on the panel line. Give assembled height, the fitted foot and the clamp their own fields so a measured bay can be checked against the same offer.

Dimension or conditionCatalogue referenceAcceptance input
Panel and aperture
2100 × 2400 mm with a 60 × 150 mm opening
Finished top line, width datum and selected 3.5 or 4.0 mm wire
Frame and insertion
32, 38, 42 or 48 mm outside tube options, with 1.5 or 2.0 mm walls and a 100 mm insertion note
Actual tube and foot fit, tube length and allowed clearance
Foot and surface
HDPE base field lists 600 × 230 × 150 mm and 15–20 kg
Selected base, allowed fixing, corner detail and handling weight
Screened bay
Screen, fence, support and ground together
Provide approved conditions and assembly-specific stability evidence

Screening belongs on the site layout

A screen changes the conditions the assembled fence needs to satisfy. Put open and screened bays on the layout with corner and end positions. We can identify the product configuration to take through your site's approval process. Identify exposed corners and screened spans on the drawing used for the site wind review.

Temporary mesh run with screen material along one section

Stage the order around installation

Plan the order in the same units your crew uses to build the perimeter. Ask for installation sequence marks if the support parts will be unloaded at different entrances.

  1. RunsBreak the continuous line into measured segments.
  2. AccessList gate openings, corners and transitions.
  3. UnloadingSeparate panel packs and small components by phase.

A kit quote includes the loose parts

Check the proposed packing list against the assembly. Count feet, clamps and braces separately so you can identify shortages early and request spares for the items that move between sites. Count spare feet and clamps against the bundles that the crew can actually open in each phase.

Temporary galvanized panels staged for a construction delivery

Frame fabrication and kit fit

The support legs, socket and top clamp form a chain of dimensions. A change to one part can affect the standing height or make a clamp sit at a different angle. Request the same fit check on the first assembly and on the shipped selections for the parts that mate.

The kit from mesh to footing
Panel and socket dimensions
  1. 60 × 150 mm mesh
  2. Selected frame tube
  3. 100 mm insertion reference
  4. Complete kit fit
Panel, tube and foot as one fitted kit
  1. Material and dimensionsSize the steel parts together

    The 2100 × 2400 mm reference panel lists 60 × 150 mm mesh. Identify the selected frame tube and base opening alongside the selected wire.

  2. Fabrication and fitFit the finished tube into the socket

    The product record gives 100 mm as its insertion reference. A fitted sample also shows seating depth, joined width and clamp position.

  3. Inspection evidenceReview the kit in its actual setting

    Record the feet, braces and clamps used on the sample. Where screening is planned, have the complete assembly reviewed for the ground and wind conditions.

Detailed checks for this order
  1. Set frame and mesh dimensionsFor welded infill, wire is arranged to the agreed grid and joined at intersections. Record the 60 × 150 mm opening and selected wire, then confirm the frame outside diameter, wall and dimensions on the same drawing.
  2. Check the frame in the baseMatch the chosen tube to the foot opening. The listing gives a 100 mm insertion reference. Record usable depth and the installed top height on a complete sample.
  3. Verify the support scheduleItemize each foot, clamp and brace. Confirm finish by part. For a screened bay, submit the full arrangement, ground conditions and wind requirements for project approval.
  4. Document the trial bayRequest an assembly drawing and the specification for the chosen components. Attach any supporting project-specific stability evidence required for the exact configuration.

TWI guidance on resistance welding · WorkSafe Victoria guidance on construction fencing

Panel options and the wind review

One item has a PVC finish in its title and a galvanized term in another field. Confirm the actual finish for every chosen part. WorkSafe Victoria flags extra wind support as a consideration when signs or shade cloth are attached. Use the full screened assembly and project conditions in that review. Record the finish choice for the legs, panels and fittings separately when you select a listing.

Standards Australia AS 4687.2 scope · WorkSafe Victoria construction site guidance

Browse related products · Temporary Fence Panels

Related fencing orders on a live site

Use the renovation guide for movable diamond-mesh panels. Use the phased project guide when the temporary run will later be replaced by a permanent fence. Pick the adjacent guide for a different frame format before comparing feet or clamps.

Share the run layout and screen details

Send the panel run lengths, screen locations and assembled height. Include socket and clamp measurements when you will reuse any parts.

Layout
Segments, corners and openings
Surface
Pavement and fixing requirements
Screen
Area and approval documents
Qingdao Relia Industries Co., Ltd.

Shuyuan Road, Qingdao, Shandong, China

About our fence business